Function Principle

The polluted solvents are heated up in a boiler made out of stainless steel and vaporize. The consistent heating up takes place via a coat of thermal oil (or vapour), which is heated up by one or several heating resistors.

A controlled thermostat and a microprocessor-controlled time controller steer the distillation and condensation. The solvent or water vapour gets through the steam collecting pipe into the radiator block and condenses there. The distillate is collected in a container and can be reused in an instant. The residues (pigments, resins, oils) stay in the boiler (recbag) and can be taken out easily after finishing the distilling process.

Field Of Application:
Mechanic-, electronic-, chemical-, pharmacy industry, as well as paints and coatings industry, resin manufacturing industry, polymer processing industry, leather and furniture industry, graphical industry...

Process Control with LCD-Display for RS 120 + RS 250 + RSi 600

  1. ON-OFF + Setting of process time
  2. LCD (Liquid Crystal Display) - explosion proof -
  3. Setting of process temperature

The long used manual timer for time control was replaced by a process control with LCD-display.

Up to now this solution, which is suitable for explosion control potentially explosive area zone 1, was not affordable. This new control is applied to units RS 120 | RS 250 | RSi 600 + DT 250 | DTi 600 as standard.

Next to a clear reading of processing times it is possible to fix the maximum process time on the processor.

  1. 0 - 5 hrs.
  2. 0 - 12 hrs.
  3. 0 - 24 hrs.